1 - 20 de 5.265
1.
Sci Rep ; 14(1): 10499, 2024 05 07.
Article En | MEDLINE | ID: mdl-38714740

Improving the efficacy of chemotherapy remains a key challenge in cancer treatment, considering the low bioavailability, high cytotoxicity, and undesirable side effects of some clinical drugs. Targeted delivery and sustained release of therapeutic drugs to cancer cells can reduce the whole-body cytotoxicity of the agent and deliver a safe localized treatment to the patient. There is growing interest in herbal drugs, such as curcumin, which is highly noted as a promising anti-tumor drug, considering its wide range of bioactivities and therapeutic properties against various tumors. Conversely, the clinical efficacy of curcumin is limited because of poor oral bioavailability, low water solubility, instability in gastrointestinal fluids, and unsuitable pH stability. Drug-delivery colloid vehicles like liposomes and nanoparticles combined with microbubbles and ultrasound-mediated sustained release are currently being explored as effective delivery modes in such cases. This study aimed to synthesize and study the properties of curcumin liposomes (CLs) and optimize the high-frequency ultrasound release and uptake by a human breast cancer cell line (HCC 1954) through in vitro studies of culture viability and cytotoxicity. CLs were effectively prepared with particles sized at 81 ± 2 nm, demonstrating stability and controlled release of curcumin under ultrasound exposure. In vitro studies using HCC1954 cells, the combination of CLs, ultrasound, and Definity microbubbles significantly improved curcumin's anti-tumor effects, particularly under specific conditions: 15 s of continuous ultrasound at 0.12 W/cm2 power density with 0.6 × 107 microbubbles/mL. Furthermore, the study delved into curcumin liposomes' cytotoxic effects using an Annexin V/PI-based apoptosis assay. The treatment with CLs, particularly in conjunction with ultrasound and microbubbles, amplified cell apoptosis, mainly in the late apoptosis stage, which was attributed to heightened cellular uptake within cancer cells.


Curcumin , Drug Delivery Systems , Liposomes , Curcumin/pharmacology , Curcumin/chemistry , Curcumin/administration & dosage , Humans , Liposomes/chemistry , Cell Line, Tumor , Drug Delivery Systems/methods , Cell Survival/drug effects , Antineoplastic Agents/pharmacology , Antineoplastic Agents/chemistry , Antineoplastic Agents/administration & dosage , Microbubbles , Breast Neoplasms/drug therapy , Breast Neoplasms/pathology , Female , Ultrasonic Waves , Drug Liberation , Apoptosis/drug effects
3.
Article En | MEDLINE | ID: mdl-38598407

Pulsed high-intensity focused ultrasound (pHIFU) can induce sparse de novo inertial cavitation without the introduction of exogenous contrast agents, promoting mild mechanical disruption in targeted tissue. Because the bubbles are small and rapidly dissolve after each HIFU pulse, mapping transient bubbles and obtaining real-time quantitative metrics correlated with tissue damage are challenging. Prior work introduced Bubble Doppler, an ultrafast power Doppler imaging method as a sensitive means to map cavitation bubbles. The main limitation of that method was its reliance on conventional wall filters used in Doppler imaging and its optimization for imaging blood flow rather than transient scatterers. This study explores Bubble Doppler enhancement using dynamic mode decomposition (DMD) of a matrix created from a Doppler ensemble for mapping and extracting the characteristics of transient cavitation bubbles. DMD was first tested in silico with a numerical dataset mimicking the spatiotemporal characteristics of backscattered signal from tissue and bubbles. The performance of DMD filter was compared to other widely used Doppler wall filter-singular value decomposition (SVD) and infinite impulse response (IIR) high-pass filter. DMD was then applied to an ex vivo tissue dataset where each HIFU pulse was immediately followed by a plane wave Doppler ensemble. In silico DMD outperformed SVD and IIR high-pass filter and ex vivo provided physically interpretable images of the modes associated with bubbles and their corresponding temporal decay rates. These DMD modes can be trackable over the duration of pHIFU treatment using k-means clustering method, resulting in quantitative indicators of treatment progression.


High-Intensity Focused Ultrasound Ablation , Microbubbles , High-Intensity Focused Ultrasound Ablation/methods , Animals , Ultrasonography, Doppler/methods , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Algorithms , Swine , Signal Processing, Computer-Assisted
4.
ACS Biomater Sci Eng ; 10(5): 3331-3342, 2024 May 13.
Article En | MEDLINE | ID: mdl-38600786

Microbubbles (MBs) hold substantial promise for medical imaging and therapy; nonetheless, knowledge gaps persist between composition, structure, and in vivo performance, especially with respect to pharmacokinetics. Of particular interest is the role of the poly(ethylene glycol) (PEG) layer, which is thought to shield the MB against opsonization and rapid clearance but is also known to cause an antibody response upon multiple injections. The goal of this study was, therefore, to elucidate the role of the PEG layer in circulation persistence of MBs in the naïve animal (prior to an adaptive immune response). Here, we directly observe the number and size of individual MBs obtained from blood samples, unifying size and concentration into the microbubble volume dose (MVD) parameter. This approach enables direct evaluation of the pharmacokinetics of intact MBs, comprising both the lipid shell and gaseous core, rather than separately assessing the lipid or gas components. We examined the in vivo circulation persistence of 3 µm diameter phospholipid-coated MBs with three different mPEG2000 content: 2 mol % (mushroom), 5 mol % (intermediate), and 10 mol % (brush). MB size and concentration in the blood were evaluated by a hemocytometer analysis over 30 min following intravenous injections of 20 and 40 µL/kg MVD in Sprague-Dawley rats. Interestingly, pharmacokinetic analysis demonstrated that increasing PEG concentration on the MB surface resulted in faster clearance. This was evidenced by a 1.6-fold reduction in half-life and area under the curve (AUC) (p < 0.05) in the central compartment. Conversely, the AUC in the peripheral compartment increased with PEG density, suggesting enhanced MB trapping by the mononuclear phagocyte system. This was supported by an in vitro assay, which showed a significant rise in complement C3a activation with a higher PEG content. In conclusion, a minimal PEG concentration on the MB shell (mushroom configuration) was found to prolong circulation and mitigate immunogenicity.


Microbubbles , Polyethylene Glycols , Polyethylene Glycols/chemistry , Polyethylene Glycols/pharmacokinetics , Animals , Phospholipids/chemistry , Rats , Male , Rats, Sprague-Dawley
5.
Nanotheranostics ; 8(3): 285-297, 2024.
Article En | MEDLINE | ID: mdl-38577322

Rationale: Microbubble (MB) contrast agents combined with ultrasound targeted microbubble cavitation (UTMC) are a promising platform for site-specific therapeutic oligonucleotide delivery. We investigated UTMC-mediated delivery of siRNA directed against epidermal growth factor receptor (EGFR), to squamous cell carcinoma (SCC) via a novel MB-liposome complex (LPX). Methods: LPXs were constructed by conjugation of cationic liposomes to the surface of C4F10 gas-filled lipid MBs using biotin/avidin chemistry, then loaded with siRNA via electrostatic interaction. Luciferase-expressing SCC-VII cells (SCC-VII-Luc) were cultured in Petri dishes. The Petri dishes were filled with media in which LPXs loaded with siRNA against firefly luciferase (Luc siRNA) were suspended. Ultrasound (US) (1 MHz, 100-µs pulse, 10% duty cycle) was delivered to the dishes for 10 sec at varying acoustic pressures and luciferase assay was performed 24 hr later. In vivo siRNA delivery was studied in SCC-VII tumor-bearing mice intravenously infused with a 0.5 mL saline suspension of EGFR siRNA LPX (7×108 LPX, ~30 µg siRNA) for 20 min during concurrent US (1 MHz, 0.5 MPa spatial peak temporal peak negative pressure, five 100-µs pulses every 1 ms; each pulse train repeated every 2 sec to allow reperfusion of LPX into the tumor). Mice were sacrificed 2 days post treatment and tumor EGFR expression was measured (Western blot). Other mice (n=23) received either EGFR siRNA-loaded LPX + UTMC or negative control (NC) siRNA-loaded LPX + UTMC on days 0 and 3, or no treatment ("sham"). Tumor volume was serially measured by high-resolution 3D US imaging. Results: Luc siRNA LPX + UTMC caused significant luciferase knockdown vs. no treatment control, p<0.05) in SCC-VII-Luc cells at acoustic pressures 0.25 MPa to 0.9 MPa, while no significant silencing effect was seen at lower pressure (0.125 MPa). In vivo, EGFR siRNA LPX + UTMC reduced tumor EGFR expression by ~30% and significantly inhibited tumor growth by day 9 (~40% decrease in tumor volume vs. NC siRNA LPX + UTMC, p<0.05). Conclusions: Luc siRNA LPXs + UTMC achieved functional delivery of Luc siRNA to SCC-VII-Luc cells in vitro. EGFR siRNA LPX + UTMC inhibited tumor growth and suppressed EGFR expression in vivo, suggesting that this platform holds promise for non-invasive, image-guided targeted delivery of therapeutic siRNA for cancer treatment.


Carcinoma, Squamous Cell , Liposomes , Animals , Mice , Liposomes/chemistry , RNA, Small Interfering/genetics , Microbubbles , Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/genetics , Carcinoma, Squamous Cell/therapy , ErbB Receptors/genetics , Luciferases
6.
Biomed Mater ; 19(4)2024 May 14.
Article En | MEDLINE | ID: mdl-38653254

Cervical carcinoma persists as a major global public health burden. While conventional therapeutic modalities inevitably cause ablation of adjacent non-tumorous tissues, photodynamic therapy (PDT) offers a targeted cytotoxic strategy through a photosensitizing agent (PS). However, the hydrophobicity and lack of selective accumulation of promising PS compounds such as zinc(II) phthalocyanine (ZnPc) impedes their clinical translation as standalone agents. The present study sought to incorporate ZnPc within double-layer hollow mesoporous silica nanoparticles (DHMSN) as nanocarriers to enhance aqueous dispersibility and tumor specificity. Owing to their compartmentalized design, the hollow mesoporous silica nanoparticles (HMSN) demonstrated enhanced ultrasonic imaging contrast. Combined with the vaporization of the perfluorocarbon perfluoropentane (PFP), the HMSN-encapsulated ZnPc enabled real-time ultrasound monitoring of PDT treatment.In vivo, the innate thermal energy induced vaporization of the DHMSN-carried PFP to significantly amplify ultrasound signals from the tumor site. Results demonstrated biocompatibility, efficient PFP microbubble generation, and robust photocatalytic activity. Collectively, this investigation establishes ultrasound-guided PDT utilizing multi-layer HMSN as a targeted therapeutic strategy for cervical malignancies with mitigated toxicity.


Fluorocarbons , Nanoparticles , Photochemotherapy , Photosensitizing Agents , Silicon Dioxide , Photochemotherapy/methods , Silicon Dioxide/chemistry , Nanoparticles/chemistry , Humans , Animals , Female , Fluorocarbons/chemistry , Photosensitizing Agents/chemistry , Photosensitizing Agents/pharmacology , Porosity , Mice , Uterine Cervical Neoplasms/drug therapy , Uterine Cervical Neoplasms/diagnostic imaging , Ultrasonography/methods , Indoles/chemistry , Microbubbles , Isoindoles , Cell Line, Tumor , HeLa Cells
7.
Int J Mol Med ; 53(6)2024 06.
Article En | MEDLINE | ID: mdl-38666537

Fibroblast growth factor (FGF)21 is a peptide hormone that improves mitochondrial function and energy metabolism, and the deficiency of its co­receptor ß­klotho (KLB) causes decreased FGF21 sensitivity. The present study examined whether the cardiac delivery of plasmids containing the KLB gene via ultrasound­targeted microbubble destruction (UTMD) enhances the efficacy of FGF21 against heart failure post­acute myocardial infarction (AMI). For this purpose, the levels of FGF21 in patients and rats with heart dysfunction post­infarction were determined using ELISA. Sprague­Dawley rats received the 3X UTMD­mediated delivery of KLB@cationic microbubbles (KLB@CMBs) 1 week following the induction of AMI. Echocardiography, histopathology and biochemical analysis were performed at 4 weeks following the induction of AMI. The results revealed that patients with heart failure post­infarction had higher serum FGF21 levels than the healthy controls. However, the downstream signal, KLB, but not α­klotho, was reduced in the heart tissues of rats with AMI. As was expected, treatment with FGF21 did not substantially attenuate heart remodeling post­infarction. It was found that decreased receptors KLB in the heart may result in the insensitivity to FGF21 treatment. In vivo, the UTMD technology­mediated delivery of KLB@CMBs to the heart significantly enhanced the effects of FGF21 administration on cardiac remodeling and mitochondrial dysfunction in the rats following infarction. The delivery of KLB to the heart by UTMD and the administration of FGF21 attenuated mitochondrial impairment and oxidative stress by activating nuclear factor erythroid 2­related factor 2 signals. On the whole, the present study demonstrates that the cardiac delivery of KLB significantly optimizes the cardioprotective effects of FGF21 therapy on adverse heart remodeling. UTMD appears a promising interdisciplinary approach with which to improve heart failure post­myocardial infarction.


Fibroblast Growth Factors , Klotho Proteins , Microbubbles , Myocardial Infarction , Rats, Sprague-Dawley , Ventricular Remodeling , Fibroblast Growth Factors/administration & dosage , Fibroblast Growth Factors/metabolism , Fibroblast Growth Factors/pharmacology , Animals , Myocardial Infarction/metabolism , Myocardial Infarction/therapy , Humans , Male , Rats , Ventricular Remodeling/drug effects , Female , Ultrasonic Waves , Myocardium/metabolism , Myocardium/pathology , Heart Failure/metabolism , Heart Failure/therapy
8.
Anticancer Res ; 44(5): 2021-2030, 2024 May.
Article En | MEDLINE | ID: mdl-38677765

BACKGROUND/AIM: In the context of surgical de-escalation in early breast cancer (EBC), this study aimed to evaluate the contrast enhancement ultrasound (CEUS) sentinel lymph node (SLN) procedure as a non-invasive axillary staging procedure in EBC in comparison with standard SLN biopsy (SLNB). PATIENTS AND METHODS: A subanalysis of the AX-CES study, a prospective single-arm, monocentric phase 3 study was performed (EudraCT: 2020-000393-20). The study included patients with EBC undergoing upfront surgery and SLN resection, with no prior history of locoregional treatment, and weighing between 40-85 kg. All patients underwent the CEUS SLN procedure as a non-invasive axillary staging procedure, with CEUS SLN accumulation marked using blue dye. After the CEUS SLN procedure, all patients underwent the standard mapping procedure. Data on success rate, systemic reactions, mean procedure time, mean surgical procedure, mean procedure without axillary staging, CEUS SLN appearance (normal/pathological), SLN number, and concordance with standard mapping procedure were collected. RESULTS: After the CEUS SLN procedure, 29 LNs among 16 patients were identified and marked. In all cases, CEUS SLN revealed at least one LN enhancement. Six (37.50%) LNs were defined as pathological after the CEUS SLN procedure. Definitive staining of CEUS SLN pathology revealed metastatic involvement in four (66.67%) of the cases. Two SLNs were identified during the CEUS SLN procedure; however, owing to the low disease burden, no change in the surgical plan was reported. CONCLUSION: The CEUS SLN procedure shows promise as a technique for non-invasive assessment of the axilla, potentially enabling safe axillary de-escalation in EBC by estimating the axillary disease burden.


Axilla , Breast Neoplasms , Contrast Media , Neoplasm Staging , Sentinel Lymph Node Biopsy , Sulfur Hexafluoride , Humans , Breast Neoplasms/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Female , Contrast Media/administration & dosage , Middle Aged , Aged , Prospective Studies , Sentinel Lymph Node Biopsy/methods , Sulfur Hexafluoride/administration & dosage , Ultrasonography/methods , Microbubbles , Lymphatic Metastasis/diagnostic imaging , Sentinel Lymph Node/pathology , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/surgery , Adult
9.
J Nanobiotechnology ; 22(1): 193, 2024 Apr 20.
Article En | MEDLINE | ID: mdl-38643134

Pyroptosis, a novel type of programmed cell death (PCD), which provides a feasible therapeutic option for the treatment of tumors. However, due to the hypermethylation of the promoter, the critical protein Gasdermin E (GSDME) is lacking in the majority of cancer cells, which cannot start the pyroptosis process and leads to dissatisfactory therapeutic effects. Additionally, the quick clearance, systemic side effects, and low concentration at the tumor site of conventional pyroptosis reagents restrict their use in clinical cancer therapy. Here, we described a combination therapy that induces tumor cell pyroptosis via the use of ultrasound-targeted microbubble destruction (UTMD) in combination with DNA demethylation. The combined application of UTMD and hydralazine-loaded nanodroplets (HYD-NDs) can lead to the rapid release of HYD (a demethylation drug), which can cause the up-regulation of GSDME expression, and produce reactive oxygen species (ROS) by UTMD to cleave up-regulated GSDME, thereby inducing pyroptosis. HYD-NDs combined with ultrasound (US) group had the strongest tumor inhibition effect, and the tumor inhibition rate was 87.15% (HYD-NDs group: 51.41 ± 3.61%, NDs + US group: 32.73%±7.72%), indicating that the strategy had a more significant synergistic anti-tumor effect. In addition, as a new drug delivery carrier, HYD-NDs have great biosafety, tumor targeting, and ultrasound imaging performance. According to the results, the combined therapy reasonably regulated the process of tumor cell pyroptosis, which offered a new strategy for optimizing the therapy of GSDME-silenced solid tumors.


Neoplasms , Pyroptosis , Humans , Pyroptosis/physiology , Microbubbles , Neoplasms/drug therapy , Apoptosis , Hydralazine/pharmacology , Hydralazine/therapeutic use
10.
Nat Commun ; 15(1): 2932, 2024 Apr 04.
Article En | MEDLINE | ID: mdl-38575577

Ultrasound localization microscopy (ULM) enables deep tissue microvascular imaging by localizing and tracking intravenously injected microbubbles circulating in the bloodstream. However, conventional localization techniques require spatially isolated microbubbles, resulting in prolonged imaging time to obtain detailed microvascular maps. Here, we introduce LOcalization with Context Awareness (LOCA)-ULM, a deep learning-based microbubble simulation and localization pipeline designed to enhance localization performance in high microbubble concentrations. In silico, LOCA-ULM enhanced microbubble detection accuracy to 97.8% and reduced the missing rate to 23.8%, outperforming conventional and deep learning-based localization methods up to 17.4% in accuracy and 37.6% in missing rate reduction. In in vivo rat brain imaging, LOCA-ULM revealed dense cerebrovascular networks and spatially adjacent microvessels undetected by conventional ULM. We further demonstrate the superior localization performance of LOCA-ULM in functional ULM (fULM) where LOCA-ULM significantly increased the functional imaging sensitivity of fULM to hemodynamic responses invoked by whisker stimulations in the rat brain.


Deep Learning , Microscopy , Rats , Animals , Microscopy/methods , Microbubbles , Ultrasonography/methods , Intravital Microscopy , Microvessels/diagnostic imaging
11.
EBioMedicine ; 102: 105066, 2024 Apr.
Article En | MEDLINE | ID: mdl-38531173

BACKGROUND: Focused ultrasound (FUS) combined with microbubbles is a promising technique for noninvasive, reversible, and spatially targeted blood-brain barrier opening, with clinical trials currently ongoing. Despite the fast development of this technology, there is a lack of established quality assurance (QA) strategies to ensure procedure consistency and safety. To address this challenge, this study presents the development and clinical evaluation of a passive acoustic detection-based QA protocol for FUS-induced blood-brain barrier opening (FUS-BBBO) procedure. METHODS: Ten glioma patients were recruited to a clinical trial for evaluating a neuronavigation-guided FUS device. An acoustic sensor was incorporated at the center of the FUS device to passively capture acoustic signals for accomplishing three QA functions: FUS device QA to ensure the device functions consistently, acoustic coupling QA to detect air bubbles trapped in the acoustic coupling gel and water bladder of the transducer, and FUS procedure QA to evaluate the consistency of the treatment procedure. FINDINGS: The FUS device passed the device QA in 9/10 patient studies. 4/9 cases failed acoustic coupling QA on the first try. The acoustic coupling procedure was repeatedly performed until it passed QA in 3/4 cases. One case failed acoustic coupling QA due to time constraints. Realtime passive cavitation monitoring was performed for FUS procedure QA, which captured variations in FUS-induced microbubble cavitation dynamics among patients. INTERPRETATION: This study demonstrated that the proposed passive acoustic detection could be integrated with a clinical FUS system for the QA of the FUS-BBBO procedure. FUNDING: National Institutes of Health R01CA276174, R01MH116981, UG3MH126861, R01EB027223, R01EB030102, and R01NS128461.


Blood-Brain Barrier , Ultrasonic Therapy , Humans , Ultrasonography , Acoustics , Ultrasonic Therapy/methods , Microbubbles , Magnetic Resonance Imaging , Brain/diagnostic imaging
12.
J Ultrasound Med ; 43(6): 1063-1080, 2024 Jun.
Article En | MEDLINE | ID: mdl-38440926

BACKGROUND: Acoustically activatable perfluoropropane droplets (PD) can be formulated from commercially available microbubble preparations. Diagnostic transthoracic ultrasound frequencies have resulted in acoustic activation (AA) predominately within myocardial infarct zones (IZ). OBJECTIVE: We hypothesized that the AA area following acute coronary ischemia/reperfusion (I/R) would selectively enhance the developing scar zone, and target bioeffects specifically to this region. METHODS: We administered intravenous PD in 36 rats and 20 pigs at various stages of myocardial scar formation (30 minutes, 1 day, and 7 days post I/R) to determine what effect infarct age had on the AA within the IZ. This was correlated with histology, myeloperoxidase activity, and tissue nitrite activity. RESULTS: The degree of AA within the IZ in rats was not associated with collagen content, neutrophil infiltration, or infarct age. AA within 24 hours of I/R was associated with increased nitric oxide utilization selectively within the IZ (P < .05 compared with remote zone). The spatial extent of AA in pigs correlated with infarct size only when performed before sacrifice at 7 days (r = .74, P < .01). CONCLUSIONS: Acoustic activation of intravenous PD enhances the developing scar zone following I/R, and results in selective tissue nitric oxide utilization.


Fluorocarbons , Myocardial Infarction , Animals , Fluorocarbons/pharmacokinetics , Swine , Rats , Myocardial Infarction/diagnostic imaging , Male , Contrast Media/pharmacokinetics , Nanoparticles , Rats, Sprague-Dawley , Myocardium/metabolism , Disease Models, Animal , Myocardial Reperfusion Injury/diagnostic imaging , Microbubbles , Female , Ultrasonography/methods
13.
Ultrason Sonochem ; 105: 106853, 2024 May.
Article En | MEDLINE | ID: mdl-38537561

Sonodynamic therapy (SDT) is an emerging antibacterial therapy. This work selected hematoporphyrin monomethyl ether (HMME) as the sonosensitizer, and studied the enhanced inhibition effect of Escherichia coli and biofilm by microbubble-mediated cavitation in SDT. Firstly, the influence of microbubble-mediated cavitation effect on different concentrations of HMME (10 µg/ml, 30 µg/ml, 50 µg/ml) was studied. Using 1,3-diphenylisobenzofuran (DPBF) as an indicator, the effect of microbubble-mediated cavitation on the production of reactive oxygen species (ROS) was studied by absorption spectroscopy. Secondly, using agar medium, laser confocal microscopy and scanning electron microscopy, the effect of microbubble-mediated cavitation on the activity and morphology of bacteria was studied. Finally, the inhibitory effect of cavitation combined with SDT on biofilm was evaluated by laser confocal microscopy. The research results indicate that: (1) Microbubble-mediated ultrasound cavitation can significantly increase cavitation intensity and production of ROS. (2) Microbubble-mediated acoustic cavitation can alter the morphological structure of bacteria. (3) It can significantly enhance the inhibition of SDT on the activity of Escherichia coli and its biofilm. Compared with the control group, the addition of microbubbles resulted in an increase in the number of dead bacteria by 61.7 %, 71.6 %, and 76.2 %, respectively. The fluorescence intensity of the biofilm decreased by 27.1 %, 80.3 %, and 98.2 %, respectively. On the basis of adding microbubbles to ensure antibacterial and biofilm inhibition effects, this work studied the influence of cavitation effect in SDT on bacterial structure, providing a foundation for further revealing the intrinsic mechanism of SDT.


Biofilms , Escherichia coli , Hematoporphyrins , Microbubbles , Reactive Oxygen Species , Escherichia coli/drug effects , Escherichia coli/physiology , Biofilms/drug effects , Reactive Oxygen Species/metabolism , Hematoporphyrins/pharmacology , Hematoporphyrins/chemistry , Ultrasonic Therapy , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry
14.
Adv Drug Deliv Rev ; 208: 115275, 2024 May.
Article En | MEDLINE | ID: mdl-38442747

Ultrasound is a promising technology to address challenges in drug delivery, including limited drug penetration across physiological barriers and ineffective targeting. Here we provide an overview of the significant advances made in recent years in overcoming technical and pharmacological barriers using ultrasound-assisted drug delivery to the central and peripheral nervous system. We commence by exploring the fundamental principles of ultrasound physics and its interaction with tissue. The mechanisms of ultrasonic-enhanced drug delivery are examined, as well as the relevant tissue barriers. We highlight drug transport through such tissue barriers utilizing insonation alone, in combination with ultrasound contrast agents (e.g., microbubbles), and through innovative particulate drug delivery systems. Furthermore, we review advances in systems and devices for providing therapeutic ultrasound, as their practicality and accessibility are crucial for clinical application.


Drug Delivery Systems , Ultrasonic Therapy , Humans , Ultrasonography , Peripheral Nervous System , Microbubbles
15.
Int J Pharm ; 655: 124015, 2024 Apr 25.
Article En | MEDLINE | ID: mdl-38527565

Sonodynamic therapy (SDT) utilizes ultrasonic excitation of a sensitizer to generate reactive oxygen species (ROS) to destroy tumor. Two dimensional (2D) black phosphorus (BP) is an emerging sonosensitizer that can promote ROS production to be used in SDT but it alone lacks active targeting effect and showed low therapy efficiency. In this study, a stable dispersion of integrated micro-nanoplatform consisting of BP nanosheets loaded and Fe3O4 nanoparticles (NPs) connected microbubbles was introduced for ultrasound imaging guided and magnetic field directed precision SDT of breast cancer. The targeted ultrasound imaging at 18 MHz and efficient SDT effects at 1 MHz were demonstrated both in-vitro and in-vivo on the breast cancer. The magnetic microbubbles targeted deliver BP nanosheets to the tumor site under magnetic navigation and increased the uptake of BP nanosheets by inducing cavitation effect for increased cell membrane permeability via ultrasound targeted microbubble destruction (UTMD). The mechanism of SDT by magnetic black phosphorus microbubbles was proposed to be originated from the ROS triggered mitochondria mediated apoptosis by up-regulating the pro-apoptotic proteins while down-regulating the anti-apoptotic proteins. In conclusion, the ultrasound theranostic was realized via the magnetic black phosphorus microbubbles, which could realize targeting and catalytic sonodynamic therapy.


Breast Neoplasms , Ultrasonic Therapy , Humans , Female , Microbubbles , Reactive Oxygen Species/metabolism , Cell Line, Tumor , Ultrasonography , Ultrasonic Therapy/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/therapy , Phosphorus , Magnetic Phenomena
16.
J Transl Med ; 22(1): 320, 2024 Mar 30.
Article En | MEDLINE | ID: mdl-38555449

BACKGROUND: Diffuse midline glioma (DMG) is a pediatric tumor with dismal prognosis. Systemic strategies have been unsuccessful and radiotherapy (RT) remains the standard-of-care. A central impediment to treatment is the blood-brain barrier (BBB), which precludes drug delivery to the central nervous system (CNS). Focused ultrasound (FUS) with microbubbles can transiently and non-invasively disrupt the BBB to enhance drug delivery. This study aimed to determine the feasibility of brainstem FUS in combination with clinical doses of RT. We hypothesized that FUS-mediated BBB-opening (BBBO) is safe and feasible with 39 Gy RT. METHODS: To establish a safety timeline, we administered FUS to the brainstem of non-tumor bearing mice concurrent with or adjuvant to RT; our findings were validated in a syngeneic brainstem murine model of DMG receiving repeated sonication concurrent with RT. The brainstems of male B6 (Cg)-Tyrc-2J/J albino mice were intracranially injected with mouse DMG cells (PDGFB+, H3.3K27M, p53-/-). A clinical RT dose of 39 Gy in 13 fractions (39 Gy/13fx) was delivered using the Small Animal Radiation Research Platform (SARRP) or XRAD-320 irradiator. FUS was administered via a 0.5 MHz transducer, with BBBO and tumor volume monitored by magnetic resonance imaging (MRI). RESULTS: FUS-mediated BBBO did not affect cardiorespiratory rate, motor function, or tissue integrity in non-tumor bearing mice receiving RT. Tumor-bearing mice tolerated repeated brainstem BBBO concurrent with RT. 39 Gy/13fx offered local control, though disease progression occurred 3-4 weeks post-RT. CONCLUSION: Repeated FUS-mediated BBBO is safe and feasible concurrent with RT. In our syngeneic DMG murine model, progression occurs, serving as an ideal model for future combination testing with RT and FUS-mediated drug delivery.


Blood-Brain Barrier , Glioma , Humans , Rats , Child , Male , Mice , Animals , Disease Models, Animal , Rats, Sprague-Dawley , Brain Stem , Drug Delivery Systems/methods , Magnetic Resonance Imaging , Glioma/radiotherapy , Microbubbles , Brain
17.
Ultrasound Med Biol ; 50(6): 888-897, 2024 Jun.
Article En | MEDLINE | ID: mdl-38519360

OBJECTIVE: We believe our poly(lactic acid) (PLA) microbubbles are well suited for therapeutic delivery to spinal cord injury (SCI) using ultrasound-triggered bursting. We investigated the feasibility of clinical ultrasound bursting in situ, the optimal bursting parameters in vitro and the loading and release of a model bio-active DNA. METHODS: Microbubbles were tested using clinical ultrasound in a rat cadaver SCI model. Burst pressure thresholds were determined using the change in enhancement after ultrasound exposure. Resonance frequency, acoustic enhancement, sizing and morphology were evaluated by comparing two microbubble porogens, ammonium carbonate and ammonium carbamate. Oligonucleotides were loaded into the shell and released using the found optimized ultrasound bursting parameters. RESULTS: In situ imaging and bursting were successful. In vitro bursting thresholds using frequencies 1, 2.25 and 5 MHz were identified between peak negative pressures 0.2 and 0.5 MPa, believed to be safe for spinal cord. The pressure threshold decreased with decreasing frequencies. PLA bursting was optimized near the resonance frequency of 2.5 to 3.0 MHz using 2.25 MHz and not at lower frequencies. PLA microbubbles, initially with a mean size of approximately 2 µm, remained in one piece, collapsed to between 0.5 and 1 µm and did not fragment. Significantly more oligonucleotide was released after ultrasound bursting of loaded microbubbles. Microbubble-sized debris was detected when using ammonium carbamate, leading to inaccurate microbubble concentration measurements. CONCLUSION: PLA microbubbles made with ammonium carbonate and burst at appropriate parameters have the potential to safely improve intrathecal therapeutic delivery to SCI using targeted ultrasound.


Microbubbles , Spinal Cord Injuries , Animals , Rats , Spinal Cord Injuries/diagnostic imaging , Microbubbles/therapeutic use , Polymers , Disease Models, Animal , Feasibility Studies , Polyesters , Drug Delivery Systems/methods
18.
J Phys Chem B ; 128(12): 2897-2904, 2024 Mar 28.
Article En | MEDLINE | ID: mdl-38484173

In this computational study, we examine the potential of microbubble-enhanced shock waves to improve the delivery of lipid-siRNA nanoparticles across neuronal plasma membranes with the ultimate aim of enhancing brain tumor treatment. We critically evaluate several variables related to experiments, including the bubble size, the shock speed and action time, and the amount of siRNA encapsulated in the liposome. Our findings reveal that microbubble-enhanced shock waves are essential for the high delivery of small lipid vesicles (under 30 nm diameter); its corresponding variables significantly impact drug penetration and absorption rates and influence the overall efficacy of the drug delivery system. Long-time recovery simulations further provide valuable insights into the self-healing ability of the plasma membrane following shock wave exposure and the subsequent absorption dynamics of siRNA. This work provides the dynamic process of siRNA released from lipid vesicles with shock wave and nanobubbles, thereby serving as a molecular mechanism support for developing tunable delivery systems for RNA-based therapy in brain tumors.


Drug Delivery Systems , Microbubbles , RNA, Small Interfering , Cell Membrane , Lipids
19.
Theranostics ; 14(5): 1794-1814, 2024.
Article En | MEDLINE | ID: mdl-38505609

Rationale: The acoustic stimulation of microbubbles within microvessels can elicit a spectrum of therapeutically relevant bioeffects from permeabilization to perfusion shutdown. These bioeffects ultimately arise from complex interactions between microbubbles and microvascular walls, though such interactions are poorly understood particularly at high pressure, due to a paucity of direct in vivo observations. The continued development of focused ultrasound methods hinges in large part on establishing links between microbubble-microvessel interactions, cavitation signals, and bioeffects. Methods: Here, a system was developed to enable simultaneous high-speed intravital imaging and cavitation monitoring of microbubbles in vivo in a chorioallantoic membrane model. Exposures were conducted using the clinical agent DefinityTM under conditions previously associated with microvascular damage (1 MHz, 0.5-3.5 MPa, 5 ms pulse length). Results: Ultrasound-activated microbubbles could be observed and were found to induce localized wall deformations that were more pronounced in smaller microvessels and increased with pressure. A central finding was that microbubbles could extravasate from microvessels (from 34% of vessels at 1 MPa to 79% at 3 MPa) during insonation (94% within 0.5 ms) and that this occurred more frequently and in progressively larger microvessels (up to 180 µm) as pressure was increased. Following microbubble extravasation, transient or sustained red blood cell leakage ensued at the extravasation site in 96% of cases for pressures ≥1 MPa. Conclusions: The results here represent the first high-speed in vivo investigation of high-pressure focused ultrasound-induced microbubble-microvessel interactions. This data provides direct evidence that the process of activated microbubble extravasation can occur in vivo and that it is linked to producing microvessel wall perforations of sufficient size to permit red blood cell leakage. The association of red blood cell leakage with microbubble extravasation provides mechanistic insight into the process of microvessel rupture, which has been widely observed in histology.


Chorioallantoic Membrane , Microbubbles , Animals , Microscopy , Ultrasonography/methods , Intravital Microscopy
20.
Int J Cardiol ; 404: 131943, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38458386

BACKGROUND: Previous studies have demonstrated the efficacy of ultrasound-targeted microbubble destruction (UTMD) in the treatment of ischemic heart failure (HF). The purpose of this study was to explore the mechanism by which UTMD improves ischemic HF. METHODS: An ischemic heart failure model was established using Sprague-Dawley rats. Rats were randomly divided into 7 groups: sham group, HF group, HF + MB group, HF + ultrasound (US) group, HF + UTMD group, HF + UTMD+LY294002 group, and HF + LY294002 group. Serum BNP level and echocardiographic parameters were measured to evaluate cardiac function. PI3K/Akt/eNOS signaling pathway protein levels were detected by immunohistochemistry (IHC) and western blotting. The concentrations of nitrous oxide (NO) and ATP were detected by ELISA, and hematoxylin and eosin (HE) staining was used to evaluate myocardial tissue. RESULTS: UTMD rapidly improved ejection fraction (EF) (HF: 37.16 ± 1.21% vs. HF + UTMD: 46.31 ± 3.00%, P < 0.01) and fractional shortening (FS) (HF: 18.53 ± 0.58% vs. HF + UTMD: 24.05 ± 1.84%, P < 0.01) in rats with ischemic HF. UTMD activated the PI3K/AKT/eNOS signaling pathway (HF vs. HF + UTMD, P < 0.01) and promoted the release of NO and ATP (HF vs. HF + UTMD, both, P < 0.05). Inhibition of the PI3K/AKT/eNOS signaling pathway by LY294002 worsened EF (HF: 37.16 ± 1.21% vs. HF + LY294002: 32.73 ± 3.05%, P < 0.05), and the release of NO and ATP by UTMD (HF + UTMD vs. HF + UTMD+LY294002, P < 0.05). CONCLUSIONS: UTMD can rapidly improve cardiac function in ischemic HF by activating the PI3K/Akt/eNOS signaling pathway and promoting the release of NO and ATP.


Heart Failure , Proto-Oncogene Proteins c-akt , Rats , Animals , Rats, Sprague-Dawley , Proto-Oncogene Proteins c-akt/metabolism , Ventricular Function, Left , Microbubbles , Phosphatidylinositol 3-Kinases , Heart Failure/diagnostic imaging , Heart Failure/drug therapy , Adenosine Triphosphate
...